Contact the VUNO team anytime.
Provides information on abnormal findings and their locations in chest X-ray images to assist clinicians in reading.

Analyzes chest X-ray images with AI to assess the normal/abnormal status of 5 major findings and provides screening information on 2 pulmonary diseases based on finding combinations.
Provides location information and confidence scores (%) for abnormal findings
Provides pulmonary disease screening information based on finding combinations
Provides quantitative metrics for cardiac size assessment as an optional feature
With the assistance of VUNO Med®-Chest X-ray™, the average JAFROC FOM of 6 readers increased by 0.058, from 0.895 to 0.953.
*JAFROC FOM = Area under the JAFROC (Jackknife adjusted free-response receiver operating characteristic) curve
With the assistance of VUNO Med®-Chest X-ray™, the average reading time of 6 readers decreased by approximately 9.41 seconds per image, from 18.85 seconds to 9.44 seconds.
Links to news about VUNO (excluded from medical device advertisement review)
This section is excluded from medical device advertisement review; it links to news related to our company.
Data and patients' personal medical information related to the use of this product must be used in accordance with the Medical Service Act and the Personal Information Protection Act, and must not be leaked externally. The cybersecurity-related items in the product approval are as follows. · User authentication: To block unauthorized access, all users go through a registration process and can access the system only through the user authentication system. · Transmission protection: Medical information exchanged between the server and client is transmitted over HTTPS using the SSL security protocol to prevent leakage, forgery, and tampering. · Update integrity: Updates are authorized by verifying the hash value generated from the update file.
Abnormal regions are marked on the chest X-ray image with outlines and colors, along with a probability value (%) for the presence of each finding.
Yes. It can be used in integration with PACS environments that process chest X-ray images in the DICOM standard.
Ad review no.: 62026-|10-36-4545 (valid until 2029-10-12)│This product is a ‘medical device’. Read the ‘precautions for use’ and the ‘instructions for use’ carefully before use.│Category : Digital medical device│Intended use : Software that detects abnormal regions in chest X-ray images (indicated with contours, colors, etc.) to assist the diagnostic decisions of the reading physician